2.1.8.1. Guidelines: ADC Sequencer in Modular Dual ADC Core IP Core

Follow these sequencer guidelines if you use dual ADC blocks with the Modular Dual ADC Core IP core.
  • The conversion sequence length of both ADC blocks must be the same.
  • You can configure independent patterns for the conversion sequence of each ADC blocks.
  • You can set a sequencer slot in ADC2 to NULL. If you set the slot to NULL, ADC2 performs a dummy conversion for the slot with output of "0". The NULL option is available only for ADC2.