H-Tile Hard IP Ethernet Intel® FPGA IP User Guide: Stratix® 10 Devices

ID 683430
Date 4/09/2024
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

B.1.26. Link Training Frame Contents for Lane 1

Provides CSRs for the following fields that are transmitted during link training to the link partner for Lane 1
  • TX EQ Coefficient Request to Link Partner on Lane 1
  • INIT Coefficients command to Link Partner on Lane 1
  • PRESET Coefficients command to Link Partner on Lane 1
  • Local TX EQ Coefficient Status for Lane 1
  • Local Receiver Ready Status for Lane 1
  • Most Recent TX EQ Coefficient Request from Link Partner on Lane 1
  • Most Recent INIT command from Link Partner on Lane 1
  • Most Recent PRESET command from Link Partner on Lane 1
  • Most Recent TX EQ Status from Link Partner on Lane 1
  • Most Recent Receiver Ready Status from Link Partner on Lane 1

Offset: 0xE1

Access: RO and RW

Link Training Frame Contents for Lane 1 Fields

Bit Name Description Access Reset
30 lp_receiver_ready_ln1 Link Partner Receiver Ready Status for Lane 1

1: The link partner receiver has determined that training is complete and is prepared to receive data

0: The link partner receiver is requesting that training continue

RO 0x0
29:24 lp_coefficient_status_ln1 TX EQ Coefficient Status from Link Partner for Lane 1

[5:4] Status of Link Partner (+1) TX EQ Coefficient

[3:2] Status of Link Partner (0) TX EQ Coefficient

[1:0] Status of Link Partner (-1) TX EQ Coefficient

The Coefficient values are encoded as follows:
  • 2'b00: Hold
  • 2'b01: Increment
  • 2'b10: Decrement
  • 2'b11: Reserved
RO 0x0
23 lp_preset_coefficients_ln1 PRESET Command from Link Partner on Lane 1

1: Set local TX EQ to PRESET

0: Normal Operation

This Field is normally Read-only, and the values are normally controlled by the Remote Partner Link Training SM.

When ovride_local_coef_enable=1, this field becomes writable, and is used to set the local values.

When ovride_local_coef_enable=1, use updated_local_coef_ln1=1 to write the local values.

RW 0x0
22 lp_initialize_coefficients_ln1 INIT Command from Link Partner on Lane 1

1: Set local TX EQ to INIT

0: Normal Operation

This field is normally Read-only, and the values are normally controlled by the Remote Partner Link Training SM.

When ovride_local_coef_enable=1, this field becomes writable, and is used to set the local values.

When ovride_local_coef_enable=1, use updated_local_coef_ln1=1 to write the local values

RW 0x0
21:16 lp_coefficient_update_ln1 TX EQ Coefficient Request from Link Partner on Lane 1

[5:4] Control for Local (+1) TX EQ Coefficient

[3:2] Control for Local (0) TX EQ Coefficient

[1:0] Control for Local (-1) TX EQ Coefficient

This field is normally Read-only, and the values are normally controlled by the Remote Partner Link Training SM.

When ovride_local_coef_enable=1, this field becomes writable, and is used to set the local values.

When ovride_local_coef_enable=1, use updated_local_coef_ln1=1 to write the local values.

The Coefficient values are encoded as follows:
  • 2'b00: Hold
  • 2'b01: Increment
  • 2'b10: Decrement
  • 2'b11: Reserved
RW 0x0
14 ld_receiver_ready_ln1 Local Receiver Ready Status for Lane 1

1: The local device receiver has determined that training is complete and is prepared to receive data

0: The local device receiver is requesting that training continue

RO 0x0
13:8 ld_coefficient_status_ln1 Local TX EQ Coefficient Status for Lane 1

[5:4] Status of Local (+1) TX EQ Coefficient

[3:2] Status of Local (0) TX EQ Coefficient

[1:0] Status of Local (-1) TX EQ Coefficient

The Coefficient values are encoded as follows:
  • 2'b00: Hold
  • 2'b01: Increment
  • 2'b10: Decrement
  • 2'b11: Reserved
RO 0x0
7 ld_preset_coefficients_ln1 PRESET Coefficients command to Link Partner on Lane 1

1: PRESET Coefficients

0: Normal Operation

This Field is normally Read-only, and the values are normally controlled by the Link Training SM.

When ovride_lp_coef_enable=1, this field becomes writable, and is used to set the values sent to the Link Partner.

When ovride_lp_coef_enable=1, use updated_lp_coef_ln1=1 to transmit the values to the Link Partner.

The PRESET command is defined in IEEE 802.3 CL72.6.10.2.3.1.

RW 0x0
6 ld_initialize_coefficients_ln1 INIT Coefficients command to Link Partner on Lane 1

1: INIT Coefficients

0: Normal Operation

This field is normally Read-only, and the values are normally controlled by the Link Training SM.

When ovride_lp_coef_enable=1, this field becomes writable, and is used to set the values sent to the Link Partner.

When ovride_lp_coef_enable=1, use updated_lp_coef_ln1=1 to transmit the values to the Link Partner.

The INIT command is defined in IEEE 802.3 CL72.6.10.2.3.2.

RW 0x0
5:0 ld_coefficient_update_ln1 TX EQ Coefficient Request to Link Partner on Lane 1

[5:4] Control for Link Partner (+1) TX EQ Coefficient

[3:2] Control for Link Partner (0) TX EQ Coefficient

[1:0] Control for Link Partner (-1) TX EQ Coefficient

This field is normally Read-only, and the values are normally controlled by the Link Training SM.

When ovride_lp_coef_enable=1, this field becomes writable, and is used to set the values sent to the Link Partner.

When ovride_lp_coef_enable=1, use updated_lp_coef_ln0=1 to transmit the values to the Link Partner.

The Coefficient values are encoded as follows:
  • 2'b00: Hold
  • 2'b01: Increment
  • 2'b10: Decrement
  • 2'b11: Reserved
RW 0x0