23.1. Trace System Parameter Settings

Table 73.  Trace System Parameter Settings
Parameter Value Description
Export interfaces for connection to manual debug fabric Yes or No If you select USB as the connection to host, selecting Yes shows the usb_if conduit— enables you to manually connect this interface.
Connection to host
  • JTAG
  • USB
Select the type of connection to the host running the System Console.
Bit width of capture interface(s) 8–128, Default = 32 Select the data bus width of the Avalon-ST interface sending the captured information.
Number of inputs 2–16, Default = 2 Select the number of trace monitors which will be connected to this trace system.
Buffer size 8192–65536, Default = 32768 Select the size of the jitter buffer in bytes.
Insert pipeline stages On or Off Turn on to insert the pipeline stages within the trace system. Turning on this parameter gives a higher fmax but uses more logic.