V-Series Transceiver PHY IP Core User Guide

ID 683171
Date 7/26/2022
Public
Document Table of Contents

20.3.2.17. XCVR_TX_PRE_EMP_1ST_POST_TAP

Pin Planner and Assignment Editor Name

Transmitter Pre-emphasis First Post-Tap

Description

Specifies the first post-tap setting value.

Note: This parameter must be set in conjunction with XCVR_TX_VOD, XCVR_TX_PRE_EMP_2ND_POST_TAP, and XCVR_TX_PRE_EMP_PRE_TAP. All combinations of these settings are not legal. Refer to the Arria V GZ Device Datasheet for more information.

Options

0–31

Assign To

Pin - TX serial data