2.2.1.15. Miscellaneous Control Signals

Table 21.  Miscellaneous Control Signals
Signal Name Width Direction Description
snapshot_active_i 1 Input Triggers the MACsec statistic counters snapshot. Reading statistics registers while the snapshot_active_i signal is asserted returns the snapshot buffer contents. Note that this signal is only visible when the Snapshot Enable parameter is enabled in the IP Parameter Editor GUI. This signal is synchronous to app_ip_st_clk.