AN 950: Temperature Excursions: for Intel® Stratix® 10 and Intel Agilex® 7 F-Series/I-Series Device Families

ID 713583
Date 10/02/2023
Public

3. Temperature Excursion Allowances and Limitations

The table below shows the allowed temperature excursion for each Intel® Stratix® 10 and Intel Agilex® 7 (F-Series and I-Series) device.

Intel has assessed the impact of such temperature excursions on device reliability and determined that device lifetime still achieves a minimum of 11.4 years.

Important: For all Intel® Stratix® 10 and Intel Agilex® 7 (F-Series and I-Series) devices, configuration is not supported in the excursion junction temperature range above 100°C.
Table 2.  Temperature Excursion Definitions
Products Speed Excursion Junction Temperature Excursion Duration (% of lifetime or total hours)
Intel® Stratix® 10 GX, Intel® Stratix® 10 DX, Intel® Stratix® 10 SX, Intel® Stratix® 10 TX All 100°C to 105°C Up to 5% or a total of accumulative 5,000 hours.

For the remaining time of 95% or a cumulative of 95,000 hours, junction temperature must not exceed 100°C.

100°C to 110°C Up to 4.1% or a total of accumulative 4,100 hours.

For the remaining time of 95.9% or a cumulative of 95,900 hours, junction temperature must not exceed 100°C.

Intel Agilex® 7 (F-Series and I-Series) with E-Tile, F-Tile, P-tile, and R-tile All 100°C to 105°C Up to 5% or a total of accumulative 5,000 hours.

For the remaining time of 95% or a cumulative of 95,000 hours, junction temperature must not exceed 100°C.

100°C to 110°C Up to 4.1% or a total of accumulative 4,100 hours.

For the remaining time of 95.9% or a cumulative of 95,900 hours, junction temperature must not exceed 100°C.

Note:
  • For specific telecom applications, refer to specific conditions requested by Telecom Telcordia NEBs GR-63; excursion should not exceed 360 hours per year, with a maximum of 96 consecutive hours.
  • For temperature excursions different from those in the above table, contact Intel Premiere Support and quote issue ID #14016709431.
  • Intel Agilex® 7 F-Series and I-Series devices with F-tile applies to 2024 product date-code or later.
  • Intel Agilex® 7 M-Series devices are not included.
  • Intel® Stratix® 10 devices with HBM are excluded due to the HBM requirement to not exceed 95°C maximum temperature.