3.10.2.1. D2H Descriptor Format (d2hdm_desc)
Name | Width | Description |
---|---|---|
SRC_ADDR [63:0] | 64 | Starting local memory address of allocated transmit buffer read by DMA and instruction must be DMWr for DMA operation with MM_mode=1. Application specific bit indicates whether this command is an Interrupt.
If App_specific_bit=001, MM_mode=0:
|
DEST_ADDR [127:64] | 64 | Destination system address where the DM sends the data to in the host memory.
When MM_mode=0, instruction is DMWr, app_specific_bits=001
|
PYLD_CNT [147:128] | 20 | DMA payload size in bytes. Max 1 MB, with 20’h0 indicating 1 MB . |
DM_FmtType [155:148] | 8 | ‘h60: DMWr |
RSVD [159:156] | 1 | Reserved |
PFVF [175:160] | 16 | {VF_ACTIVE, VFNUM[10:0], PF[3:0]} |
MM_mode [176:176] | 1 | MM_mode=0: Only when Write back is intended. It is illegal and behavior is undefined if a DMRd is instructed with MM_Mode=0; MM_mode=1: Indication to D2H DM to transfer the data to Host side. MM_mode=1 with DMWr command enables reading local FPGA memory and writing to host memory. |
App_specific_bits [179:177] | 3 | Application-specific bits. An example use case is that the external DMA controller set these bits to generate the Interrupt.
Note: In Intel® Quartus® Prime 22.1 release, D2H Data Mover doesn't support Interrupt generation.
|
DESC_IDX1 [195:180] | 16 | Unique Identifier for each descriptor, the same ID will be applied AVST source status signaling (d2hdm_desc_status) returning the status of the data mover completion to DMA controller. |
RSVD [196:196] | 1 | Reserved |
RSVD [212:197] | 16 | Reserved |
DESC_IDX2 [224:213] | 12 | Optional. Descriptor ID field providing additional provision for descriptor fetch engine to embed information such as channel number, etc. which the completion status on AVST will return unedited for the response completion packet. If not used, the user external DMA controller is expected to drive this field to zero. The data mover subsystem will treat the descriptor ID field as {DESC_IDX2, DESC_IDX1}. |