Intel® Quartus® Prime Pro Edition User Guide: Debug Tools
A newer version of this document is available. Customers should click here to go to the newest version.
Visible to Intel only — GUID: mwh1410384625824
Ixiasoft
Visible to Intel only — GUID: mwh1410384625824
Ixiasoft
2.4.6.2. Nested Trigger Conditions
The evaluation precedence of a nested trigger condition starts at the bottom-level with the leaf-groups. The logic analyzer uses the resulting logic value to compute the parent group’s logic value. If you manually set the value of a group, the logic value of the group's members doesn't influence the result of the group trigger.
- Select Basic OR under Trigger Conditions.
- In the Setup tab, select several nodes. Include groups in your selection.
- Right-click the Setup tab and select Group.
- Select the nested group and right-click to set a group trigger condition that applies the reduction AND, OR, NAND, NOR, XOR, XNOR, or logical TRUE or FALSE.
Note: You can only select OR and AND group trigger conditions for bottom-level groups (groups with no groups as children).Figure 37. Applying Trigger Condition to Nested Group