Intel® Stratix® 10 Configuration User Guide

ID 683762
Date 10/04/2021
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

5.1.2. Remote System Update Using AS Configuration

Remote system update using AS configuration includes the following components:

  • Your remote system update host design. The host can be custom logic, the HPS, or a Nios® II processor in the FPGA.
  • One factory image.
  • Flash memory for image storage.
  • At least one application image.
  • Designs that do not use the HPS as the remote system update host require a Mailbox Client Intel® FPGA IP as shown in the figure below. The Mailbox Client sends and receives remote system update operation commands and responses, such as QSPI_READ and QSPI_WRITE.
    Figure 62.  Intel® Stratix® 10 Remote System Update Components
Attention:

Starting in version 19.2 of the Intel® Quartus® Prime software, a restriction applies to the following mailbox client IPs that access the SDM mailbox over an Avalon® Memory-Mapped ( Avalon® -MM) interface:

  • Temperature Sensor
  • Voltage Sensor
  • Chip ID
  • Serial Flash Mailbox Client
  • Mailbox Client IP
  • Advanced SEU Detection IP
  • Partial Reconfiguration IP

If you use the Mailbox IP in designs compiled in Intel® Quartus® Prime Pro Edition software version 19.2 or later, you must only use SDM firmware starting from version 19.2 or later to configure the FPGA.