Visible to Intel only — GUID: hco1421694858128
Ixiasoft
3.7.2. Frequency Parameters
Parameter | Value | Description |
---|---|---|
Phase Accumulator Precision | 4 to 64 | Select the required phase accumulator precision. The phase accumulator precision must be greater than or equal to the specified angular resolution. |
Angular Resolution | 4 to 24 or 32 | Select the required angular resolution. The maximum value is 24 for small and large ROM algorithms; 32 for CORDIC and multiplier-based algorithms. |
Magnitude Precision | 10 to 32 | Select the required magnitude precision. |
Implement Phase Dithering | On or Off | Turn on to implement phase dithering. |
Dither Level | Min to Max | When phase dithering is enabled you can use the slider control to adjust the dither level between its minimum and maximum values, |
Clock Rate | 1 to 999 MHz, kHz, Hz, mHz, | Select the clock rate using units of MegaHertz, kiloHertz, Hertz or milliHertz. |
Desired Output Frequency | 1 to 999 MHz, kHz, Hz, mHz, | Select the desired output frequency using units of MegaHertz, kiloHertz, Hertz or milliHertz. |
Phase Increment Value | — | Displays the phase increment value calculated from the clock rate and desired output frequency. |
Real Output Frequency | — | Displays the calculated value of the real output frequency. |