2.2.1. Power Supplies Monitored and Not Monitored by the POR Circuitry
Power Supply Device Options | Power Supplies Monitored | Power Supplies Not Monitored |
---|---|---|
Single-supply device |
|
— |
Dual-supply device |
|
|
The Intel® MAX® 10 POR circuitry uses an individual POR-detecting circuitry to monitor each of the configuration-related power supplies independently. The outputs of all the individual POR detectors gate the main POR circuitry. The main POR circuitry waits for all individual POR circuitries to release the POR signal before allowing the control block to start configuring the device. The main POR is released after the last ramp-up power reaches the POR trip level followed by a POR delay.
After the Intel® MAX® 10 device enters user mode, the POR circuit continues to monitor the VCCA and VCC power supplies. This is to detect a brown-out condition during user mode. If either the VCCA or VCC voltages go below the POR trip point during user mode, the main POR signal is asserted. When the main POR signal is asserted, the device is forced into reset state. VCCIO 3 is monitored by the POR circuitry. In the event of the VCCIO 3 voltage drops during user mode, the POR circuit does not reset the device. However, the POR circuit does monitor the VCCIO voltage drop for up to 9 ms after the last power rail reaches its trip point.