Interlaken (2nd Generation) Intel® FPGA IP User Guide

ID 683396
Date 10/04/2021
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

4.4.2.2. RX Error Handling

In Interlaken Look-aside mode, the IP checks for CRC24 errors in incoming data stream. For CRC24 errors, you should use crc24_err signal similar to Interlaken mode. The crc24_err signal can appear after irx_valid signal.

If there is a data word just before CRC24 errored control word, the IP copies the CRC24 error bit to the location of the last word as well as original location of CRC24 error.