8.5.2. Error Detection Frequency

You can control the speed of the error detection process by setting the division factor of the clock frequency in the Intel® Quartus® Prime software. The divisor is 2n, where n can be any value listed in the following table.

The speed of the error detection process for each data frame is determined by the following equation:

Figure 173. Error Detection Frequency Equation
Table 105.  Error Detection Frequency Range for Cyclone® V DevicesThe following table lists the frequencies and valid values of n.
Internal Oscillator Frequency Error Detection Frequency n Divisor Range
Maximum Minimum
100 MHz 100 MHz 390 kHz 0, 1, 2, 3, 4, 5, 6, 7, 8 1 – 256