DSP Builder for Intel® FPGAs (Advanced Blockset): Handbook

ID 683337
Date 5/01/2023
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

15.4.32. Left Shift (LShift)

The LShift block outputs the left shifted version of the input value.

The shift is specified by the input b:

q = (a << b)

The width of the data type a determines the maximum size of the shift. Shifts of more than the input word width result in an output of 0.

Table 205.  Parameters for the LShift Block
Parameter Description
Output data type mode Determines how the block sets its output data type:
  • Inherit via internal rule: the number of integer and fractional bits is the maximum of the number of bits in the input data types.
  • Specify via dialog: you can set the output type of the block explicitly using additional fields that are available when this option is selected. This option reinterprets the output bit pattern from the LSB up according to the specified type.
  • Boolean: the output type is Boolean.
Output data type Specifies the output data type. For example, sfix(16), uint(8).
Output scaling value Specifies the output scaling value. For example, 2^-15.
Table 206.  Port Interface for the LShift Block
Signal Direction Type Description Vector Data Support Complex Data Support
a Input Any fixed-point type Operand 1 Yes No
b Input Any fixed-point type Operand 2 Yes No
q Output Derived fixed-point type Result Yes No