12.6.4.5.3. User Notification of ECC Errors

When an ECC error occurs, an interrupt signal notifies the MPU subsystem, and the ECC error information is stored in the status registers. The memory controller provides interrupts for single-bit and double-bit errors.

The status of interrupts and errors are recorded in status registers, as follows:

  • The dramsts register records interrupt status.
  • The dramintr register records interrupt masks.
  • The sbecount register records the single-bit error count.
  • The dbecount register records the double-bit error count.
  • The erraddr register records the address of the most recent error.