The Automotive-Grade Device Handbook

ID 683121
Date 9/19/2024
Public
Document Table of Contents

5. DC and Timing Specifications

The automotive-grade devices have the same values for the following specifications as published in the respective device datasheets:

  • Absolute maximum ratings
  • Recommended operating conditions
  • DC electrical characteristics
  • Timing specifications over the automotive temperature range

For the maximum power-up current (ICCINT) required to power up an automotive-grade Cyclone® device, use the value specified for the corresponding industrial-grade device.

The on-chip series termination (RS OCT) specifications for the following automotive-grade devices are as follows:

  • Automotive-grade Cyclone® III, Cyclone® IV, Cyclone® V, Cyclone® V SoC, Cyclone® 10 LP, and MAX® 10 devices—same as the corresponding industrial-grade devices
  • Automotive-grade Cyclone® II devices—same as the corresponding extended-temperature devices

The switching characteristics for the following automotive-grade devices are as follows:

  • Automotive-grade Cyclone® III, Cyclone® IV, Cyclone® V, and Cyclone® V SoC devices—same as the devices with –8 speed grade as published in the respective device datasheets
  • Automotive-grade MAX® II and MAX® V devices—same as the devices with –5 speed grade as published in the respective device datasheets