1.1. Altera IP Catalog and Parameter Editor
1.2. Installing and Licensing Altera* IP Cores
1.3. Best Practices for Altera* IP
1.4. IP General Settings
1.5. Specifying the IP Parameters and Options ( Quartus® Prime Pro Edition)
1.6. Generating IP Cores ( Quartus® Prime Standard Edition)
1.7. Generating Example Designs for Altera* IP
1.8. Modifying an IP Variation
1.9. Upgrading IP Cores
1.10. Simulating Altera* IP Cores
1.11. Synthesizing IP Cores in Other EDA Tools
1.12. Support for the IEEE 1735 Encryption Standard
1.13. Introduction to Altera* IP Cores Revision History
1.14. Introduction to Altera* IP Cores Archives
1.10.4.1.1. Sourcing Aldec ActiveHDL* or Riviera Pro* Simulator Setup Scripts
1.10.4.1.2. Sourcing Cadence Incisive* Simulator Setup Scripts
1.10.4.1.3. Sourcing Cadence Xcelium* Simulator Setup Scripts
1.10.4.1.4. Sourcing QuestaSim* Simulator Setup Scripts
1.10.4.1.5. Sourcing Synopsys VCS* (2-Step) Simulator Setup Scripts
1.10.4.1.6. Sourcing Synopsys VCS* (3-Step) Simulator Setup Scripts
Visible to Intel only — GUID: mwh1409958282683
Ixiasoft
1.6. Generating IP Cores ( Quartus® Prime Standard Edition)
This topic describes parameterizing and generating an IP variation using a legacy parameter editor in the Quartus® Prime Standard Edition software.
Figure 10. Legacy Parameter Editors
- In the IP Catalog (Tools > IP Catalog), locate and double-click the name of the IP core to customize. The parameter editor appears.
- Specify a top-level name and output HDL file type for your IP variation. This name identifies the IP core variation files in your project. Click OK. Do not include spaces in IP variation names or paths.
- Specify the parameters and options for your IP variation in the parameter editor. Refer to your IP core user guide for information about specific IP core parameters.
- Click Finish or Generate (depending on the parameter editor version). The parameter editor generates the files for your IP variation according to your specifications. Click Exit if prompted when generation is complete. The parameter editor adds the top-level .qip file to the current project automatically.
Note: For devices released prior to Arria® 10 devices, the generated .qip and .sip files must be added to your project to represent IP and Platform Designer systems. To manually add an IP variation generated with legacy parameter editor to a project, click Project > Add/Remove Files in Project and add the IP variation .qip file.