Visible to Intel only — GUID: mwh1410383429190
Ixiasoft
1.1. Altera IP Catalog and Parameter Editor
1.2. Installing and Licensing Altera* IP Cores
1.3. Best Practices for Altera* IP
1.4. IP General Settings
1.5. Specifying the IP Parameters and Options ( Quartus® Prime Pro Edition)
1.6. Generating IP Cores ( Quartus® Prime Standard Edition)
1.7. Generating Example Designs for Altera* IP
1.8. Modifying an IP Variation
1.9. Upgrading IP Cores
1.10. Simulating Altera* IP Cores
1.11. Synthesizing IP Cores in Other EDA Tools
1.12. Support for the IEEE 1735 Encryption Standard
1.13. Introduction to Altera* IP Cores Revision History
1.14. Introduction to Altera* IP Cores Archives
1.10.4.1.1. Sourcing Aldec ActiveHDL* or Riviera Pro* Simulator Setup Scripts
1.10.4.1.2. Sourcing Cadence Incisive* Simulator Setup Scripts
1.10.4.1.3. Sourcing Cadence Xcelium* Simulator Setup Scripts
1.10.4.1.4. Sourcing QuestaSim* Simulator Setup Scripts
1.10.4.1.5. Sourcing Synopsys VCS* (2-Step) Simulator Setup Scripts
1.10.4.1.6. Sourcing Synopsys VCS* (3-Step) Simulator Setup Scripts
Visible to Intel only — GUID: mwh1410383429190
Ixiasoft
1.10.5.1. Setting Up NativeLink Simulation ( Quartus® Prime Standard Edition)
Before running NativeLink simulation, specify settings for your simulator in the Quartus® Prime software.
To specify NativeLink settings in the Quartus® Prime Standard Edition software, follow these steps:
- Open an Quartus® Prime Standard Edition project.
- Click Tools > Options and specify the location of your simulator executable file.
Table 9. Execution Paths for EDA Simulators Simulator Path Questa*-Intel FPGA Edition <drive letter>:\<simulator install path>\ (Windows) /<simulator install path>/bin (Linux)
Siemens EDA QuestaSim <drive letter>:\<simulator install path>\ (Windows) <simulator install path>/bin (Linux)
Synopsys VCS/VCS MX <simulator install path>/bin (Linux) Cadence Incisive Enterprise/Xcelium <simulator install path>/tools/bin (Linux) Aldec Active-HDL Aldec Riviera-PRO <drive letter>:\<simulator install path>\bin (Windows) <simulator install path>/bin (Linux)
- Click Assignments > Settings and specify options on the Simulation page and the More NativeLink Settings dialog box. Specify default options for simulation library compilation, netlist and tool command script generation, and for launching RTL or gate-level simulation automatically following compilation.
- If your design includes a testbench, turn on Compile test bench. Click Test Benches to specify options for each testbench. Alternatively, turn on Use script to compile testbench and specify the script file.
- To use a script to setup a simulation, turn on Use script to setup simulation.