External Memory Interface Handbook Volume 3: Reference Material: For UniPHY-based Device Families

ID 683841
Date 3/06/2023
Public
Document Table of Contents

1.15.2.2. Ping Pong PHY Calibration

The sequencer treats the Ping Pong PHY as a regular interface of double the width. For example, in the case of two x16 devices, the sequencer calibrates both devices together as a x32 interface. The sequencer chip select signal fans out to both devices so that they are treated as a single interface. The VFIFO calibration process is unchanged. For LFIFO calibration, the LFIFO buffer is duplicated for each interface and the worst-case read datapath delay of both interfaces is used.