13.6.1. Access Protocol
The communication protocol to send commands from user logic to the sequencer uses a multistep handshake with a data structure as shown below, and an algorithm as shown in the figure which follows.
typedef struct_debug_data_struct { ... // Command interaction alt_u32 requested_command; alt_u32 command_status; alt_u32 command_parameters[COMMAND_PARAM_WORDS];... }
To send a command to the sequencer, user logic must first poll the command_status word for a value of TCLDBG_TX_STATUS_CMD_READY, which indicates that the sequencer is ready to accept commands. When the sequencer is ready to accept commands, user logic must write the command parameters into command_parameters, and then write the command code into requested_command.
The sequencer detects the command code and replaces command_status with TCLDBG_TX_STATUS_CMD_EXE, to indicate that it is processing the command. When the sequencer has finished running the command, it sets command_status to TCLDBG_TX_STATUS_RESPONSE_READY to indicate that the result of the command is available to be read. (If the sequencer rejects the requested command as illegal, it sets command_status to TCLDBG_TX_STATUS_ILLEGAL_CMD.)
User logic acknowledges completion of the command by writing TCLDBG_CMD_RESPONSE_ACK to requested_command. The sequencer responds by setting command_status back to STATUS_CMD_READY. (If an illegal command is received, it must be cleared using CMD_RESPONSE_ACK.)