Visible to Intel only — GUID: xkv1519852295211
Ixiasoft
1.1. What's New In This Version
1.2. Partial Reconfiguration Terminology
1.3. Partial Reconfiguration Process Sequence
1.4. Internal Host Partial Reconfiguration
1.5. External Host Partial Reconfiguration
1.6. Partial Reconfiguration Design Flow
1.7. Partial Reconfiguration Design Considerations
1.8. Hierarchical Partial Reconfiguration
1.9. Partial Reconfiguration Design Timing Analysis
1.10. Partial Reconfiguration Design Simulation
1.11. Partial Reconfiguration Design Debugging
1.12. Partial Reconfiguration Security ( Stratix® 10 Designs)
1.13. PR Bitstream Compression and Encryption ( Arria® 10 and Cyclone® 10 GX Designs)
1.14. Avoiding PR Programming Errors
1.15. Exporting a Version-Compatible Compilation Database for PR Designs
1.16. Creating a Partial Reconfiguration Design Revision History
1.6.1. Step 1: Identify Partial Reconfiguration Resources
1.6.2. Step 2: Create Design Partitions
1.6.3. Step 3: Floorplan the Design
1.6.4. Step 4: Add the Partial Reconfiguration Controller Intel® FPGA IP
1.6.5. Step 5: Define Personas
1.6.6. Step 6: Create Revisions for Personas
1.6.7. Step 7: Compile the Base Revision and Export the Static Region
1.6.8. Step 8: Setup PR Implementation Revisions
1.6.9. Step 9: Program the FPGA Device
1.6.9.1. Generating PR Bitstream Files
1.6.9.2. Generating PR Bitstream Files
1.6.9.3. Partial Reconfiguration Bitstream Compatibility Checking
1.6.9.4. Raw Binary Programming File Byte Sequence Transmission Examples
1.6.9.5. Generating a Merged .pmsf File from Multiple .pmsf Files ( Arria® 10 and Cyclone® 10 GX Designs)
1.7.1. Partial Reconfiguration Design Guidelines
1.7.2. PR Design Timing Closure Best Practices
1.7.3. PR File Management
1.7.4. Evaluating PR Region Initial Conditions
1.7.5. Creating Wrapper Logic for PR Regions
1.7.6. Creating Freeze Logic for PR Regions
1.7.7. Resetting the PR Region Registers
1.7.8. Promoting Global Signals in a PR Region
1.7.9. Planning Clocks and other Global Routing
1.7.10. Implementing Clock Enable for On-Chip Memories
2.1. Internal and External PR Host Configurations
2.2. Partial Reconfiguration Controller Intel FPGA IP
2.3. Partial Reconfiguration Controller Intel Arria® 10/Cyclone® 10 FPGA IP
2.4. Partial Reconfiguration External Configuration Controller Intel FPGA IP
2.5. Partial Reconfiguration Region Controller Intel® FPGA IP
2.6. Avalon® Memory-Mapped Partial Reconfiguration Freeze Bridge IP
2.7. Avalon® Streaming Partial Reconfiguration Freeze Bridge IP
2.8. Generating and Simulating Intel® FPGA IP
2.9. Quartus® Prime Pro Edition User Guide: Partial Reconfiguration Archive
2.10. Partial Reconfiguration Solutions IP User Guide Revision History
2.3.1. Agent Interface
2.3.2. Reconfiguration Sequence
2.3.3. Interrupt Interface
2.3.4. Parameters
2.3.5. Ports
2.3.6. Timing Specifications
2.3.7. PR Control Block and CRC Block Verilog HDL Manual Instantiation
2.3.8. PR Control Block and CRC Block VHDL Manual Instantiation
2.3.9. PR Control Block Signals
2.3.10. Configuring an External Host for Arria® 10 or Cyclone® 10 GX Designs
2.8.1. Specifying the IP Parameters and Options ( Quartus® Prime Pro Edition)
2.8.2. Running the Freeze Bridge Update script
2.8.3. IP Core Generation Output ( Quartus® Prime Pro Edition)
2.8.4. Arria® 10 and Cyclone® 10 GX PR Control Block Simulation Model
2.8.5. Generating the PR Persona Simulation Model
2.8.6. Secure Device Manager Partial Reconfiguration Simulation Model
Visible to Intel only — GUID: xkv1519852295211
Ixiasoft
2.4.2. Ports
The Partial Reconfiguration External Configuration Controller Intel® FPGA IP includes the following interface ports.
Port Name | Width | Direction | Function |
---|---|---|---|
pr_request | 1 | Input | Indicates that the PR process is ready to begin. The signal is a conduit not synchronous to any clock signal. |
pr_error | 2 | Output | Indicates a partial reconfiguration error.:
|
pr_done | 1 | Output | Indicates that the PR process is complete. The signal is a conduit not synchronous to any clock signal. |
start_addr | 1 | Input | Specifies the start address of PR data in Active Serial Flash. You enable this signal by selecting either Avalon® -ST or Active Serial for the Enable Avalon-ST Pins or Active Serial Pins parameter. The signal is a conduit not synchronous to any clock signal. |
reset | 1 | Input | Active high, synchronous reset signal. |
out_clock | 1 | Output | Clock source that generates from an internal oscillator. |
busy | 1 | Output | The IP asserts this signal to indicate PR data transfer in progress. You enable this signal by selecting Enable for the Enable busy interface parameter. |