Arria® 10 Transceiver PHY User Guide

ID 683617
Date 4/01/2024
Public
Document Table of Contents

9.2.5.2. Link Optimization Tests

The Transceiver Toolkit autosweep test automatically sweeps PMA ranges to determine the transceiver settings that provide the best signal integrity. The toolkit allows you to store a history of the test runs and keep a record of the best PMA settings.

To launch auto sweep, click Tools > Auto Sweep.

Figure 297. Example of Autosweep View

The Autosweep view, when launched, is not associated with any given instance(s) or instance or channel pair(s). You can create as many Autosweep views as you desire, to allow sweeping over different parameters on different channels of the same instance, or different instances entirely.