1.12. Latest Known Intel® Quartus® Prime Software Issues

Information about known issues that affect Intel® Quartus® Prime Standard Edition Version 22.1std is available in the Intel FPGA Knowledge Base.

For the latest information about issues that affect Intel® Quartus® Prime Standard Edition Version 22.1std, review the Intel FPGA Knowledge Base articles that apply to Intel® Quartus® Prime Standard Edition Version 22.1std .

Table 14.  Important Known Issues Affecting Intel® Quartus® Prime Standard Edition Version 22.1std
Description Workaround
On Microsoft* Windows* systems, SDI II Intel® FPGA IP design example generation fails with the following error message:
Error: Failed to generate example design example_design
to:: <design directory>\sdi_ii_0_example_design
For details and the availability of a fix, refer to Why does the SDI II Intel® FPGA IP design example generation fail when using the Intel® Quartus® Prime Software for Windows? in the Intel FPGA Knowledge Base.
On Microsoft* Windows* systems, the following error occurs when generating an Intel® Arria® 10 EMIF Example Design for simulation:
Error: emif_0: An error has occurred when generating the
simulation example design. See make_sim_design_errors.log for details.
Error: Failed to generate example design <design name>
to: <example design directory>
Generate Example Design: completed with errors
You can safely ignore these warning messages.

Simulation file sets for Siemens* EDA Questa* and Aldec* Riviera-PRO* simulation software are generated and contain the relevant design files to run the simulation successfully.

For more details and the availability of a fix, refer to Why does the Intel® Arria® 10 EMIF Example Design Generation Fail when using the Intel® Quartus® Prime Standard Edition Software Version 22.1 for Windows? in the Intel FPGA Knowledge Base.

When you use the Intel® Arria® 10 EMIF IP Skip Calibration mode, simulation of Intel® Arria® 10 EMIF IP with Siemens* EDA Questa* simulation software (Siemens* EDA Questa* Advanced Simulator or Questa*-Intel® FPGA Edition) can hang. Use the Abstract PHY for fast simulation simulation option to prevent the hang.

For more details and the availability of a fix, refer to Why does Simulation of Intel® Arria® 10 EMIF IP in Mentor simulators hang when using Intel® Quartus® Prime Standard Edition Software version 22.1 in the Intel FPGA Knowledge Base.

You can find known issue information for previous versions of the Quartus® Prime software on the Intel FPGA Knowledge Base web page.

Information about known software issues that affect previous versions of the Quartus® II software is available on the Intel® Quartus® Prime and Quartus II Software Support web page.