E-tile Hard IP User Guide: E-Tile Hard IP for Ethernet and E-Tile CPRI PHY Intel® FPGA IPs

ID 683468
Date 12/28/2022
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

2.9.2.13. Minimum and Maximum Reference Time (TAM) Interval for UI Measurement (Hardware)

Table 25.  Minimum and Maximum Number of Reference Time Interval Allowed for UI Measurement
Mode FEC Type Minimum Number of Reference Time Load Interval Maximum Number of Reference Time Load Interval
Number of Count, N Milliseconds (ms) Number of Count, N Miliseconds (ms)
TX RX TX RX TX RX TX RX
10G-1 No FEC 6 10 3.15 0.006 64000 64000 33554.43 39.32
25G-1 No FEC 6 10 1.26 0.002 64000 64000 13421.77 15.73
KR-FEC 6 6 1.26 1.26 64000 64000 13421.77 13421.77
100G-4 No FEC

KR-FEC

6 6 1.26 1.26 64000 64000 13421.77 13421.77