Visible to Intel only — GUID: hco1421694550374
Ixiasoft
4.1. FIR II IP Core Interpolation Filters
4.2. FIR Decimation Filters
4.3. FIR II IP Time-Division Multiplexing
4.4. FIR II IP Core Multichannel Operation
4.5. FIR II IP Multiple Coefficient Banks
4.6. FIR II IP Coefficient Reloading
4.7. Reconfigurable FIR Filters
4.8. FIR II IP Core Interfaces and Signals
Visible to Intel only — GUID: hco1421694550374
Ixiasoft
3.3.1. Loading Coefficients from a File
When you import a coefficient set, the FIR II wizard shows the frequency response of the floating-point coefficients in blue and the frequency response of the fixed-point coefficients in red. The FIR II IP supports scaling on the coefficient set.
- Click Import coefficients, in the File name box, specify the name of the .txt file containing the coefficient set.
- In the .txt file, separate the coefficients by either white space or commas or both.
- Use new lines to separate banks.
- You may use blank lines as the FIR II IP core ignores them.
- You may use floating-point or fixed-point numbers, and scientific notation.
- Use a # character to add comments.
- Specify an array of coefficient sets to support multiple coefficient sets.
- Specify the number of rows to specify the number of banks.
- All coefficient sets must have the same symmetry type and number of taps. For example: # bank 1 and 2 are symmetric 1, 2, 3, 2, 1 1 3 4 3 1 # bank 3 is anti-symmetric 1 2 0 -2 -1 # bank 4 is asymmetric 1,2,3,4,5