1.1. Military Temperature Support

The switching characteristic of the military-temperature grade Intel® Arria® 10 devices is the same as the devices with -I3 FPGA fabric speed grade and transceiver speed grade 4 as indicated in the Intel® Arria® 10 Device Datasheet, with exceptions described below:

  • Supported temperature range:
    • Ambient and junction temperature of –55°C during device power-up and configuration.
    • Ambient temperature of –55⁰C for device functionality support and complies with Intel® Arria® 10 performance specifications using timing model corresponding to temperature junction range from –40°C to 125°C.
  • Transceiver capable of driving backplane up to 13 decibels (dB) only.
  • DDR4 maximum performance at 800 MHz.
  • For military grade devices, the VCCLSENSE and GNDSENSE to the voltage regulators must be connected and used.
  • On-chip termination (OCT) calibration resistance tolerances:
    OCT IO Standard Tolerances (%)
    RT POD12 ±20
    SSTL and HSTL -15 to 40
    RS All supported I/O standard ±20
    Note: To understand the impact of termination impedance variation, Intel® recommends that you perform signal integrity simulation using the IBIS or HSPICE models.

The military-temperature grade Intel® Arria® 10 devices support the following serial interface IPs:

  • PCI Express* ( PCIe* ) IP Gen1 and Gen2 x1, x2, x4, and x8 modes. Gen3 x1 and x2 modes only.
  • Triple-Speed Ethernet IP in GXB mode.
  • Low Latency Ethernet 10G MAC IP in 10G mode.

For more information about Ethernet IP or other IP-related support, submit a Service Request at the My Intel support page.

Prototyping industrial temperature grade devices may be substituted for military temperature range devices due to the shorter lead time.

Note: You must use and close timing with the Intel® Quartus® Prime Pro Edition software with military OPNs. Timing and performance for military OPNs at extended temperatures differ from standard devices. Contact Intel® for acceptable mission profiles.

Use the following guidelines to compile your design using the Intel® Quartus® Prime Pro Edition software for industrial or military devices:

  • When using military models with military devices, select an applicable military speed grade 3 (M3) part code and compile or recompile your design.
  • When using military models with industrial devices, select an applicable industrial speed grade 3 (I3) part code and update the Operating Settings and Conditions dialog box to reflect –55°C (Minimum) and 125°C (Maximum) temperatures before compiling or recompiling your design.
Table 1.   Intel® Arria® 10 Industrial and Military Temperature Device Part Numbers
Item Device Part Number Package
Military Temperature Industrial Temperature
1 10AX016C4U19M3SG 10AX016C4U19I3SG U19
2 10AX016E4F29M3SG 10AX016E4F29I3SG F29
3 10AX022C4U19M3SG 10AX022C4U19I3SG U19
4 10AX022E4F29M3SG 10AX022E4F29I3SG F29
5 10AX115N4F40M3SG 10AX115N4F40I3SG F40
6 10AX048E4F29M3SG 10AX048E4F29I3SG F29
7 10AX048K4F35M3SG 10AX048K4F35I3SG F35
8 10AX057K4F35M3SG 10AX057K4F35I3SG F35
9 10AX057N4F40M3SG 10AX057N4F40I3SG F40
10 10AX066K4F35M3SG 10AX066K4F35I3SG F35
11 10AX066N4F40M3SG 10AX066N4F40I3SG F40
12 10AS027E4F29M3SG 10AS027E4F29I3SG F29
13 10AS048H4F34M3SG 10AS048H4F34I3SG F34
14 10AS066N4F40M3SG 10AS066N4F40I3SG F40
Note: Contact your Intel® support representative to evaluate on your operating usage profile before ordering the military devices.