The following tables describe the ISR handler recommendations for different TX and RX error types.

Table 18.  TX Interrupt Handler Recommendations
Error Type ISR Handler Operation
tx_sysref_lemc_err
  • This error occurs when the SYSREF signal continuously resets the LEMC counter at an unexpected time, which violates the LEMC period.
  • The processor needs to check the setting for all LEMC counters configured on the JESD204C IP converter device and clock chip.
tx_dll_data_invalid_err
  • This error occurs when data bubble appears on the Avalon® streaming interface in the JESD204C TX base core.
  • The processor needs to probe the upstream device the find out why it has stalled and take further action.
Note: By design, you should calculate the data throughput to ensure that there are no data bubbles in the design. This additional protection is to minimize errors in the system.
tx_frame_data_invalid_err
  • This error occurs when data bubble appears on the Avalon® streaming interface in the JESD204C TX transport layer.
  • The processor needs to probe the upstream device the find out why it has stalled and take further action.
Note: By design, you should calculate the data throughput to ensure that there are no data bubbles in the design. This additional protection is to minimize errors in the system.
cmd_invalid_err
  • This error occurs when data bubble appears on the Avalon® streaming command interface in the JESD204C TX link layer.
  • The processor needs to probe the upstream device the find out why it has stalled and take further action.
Note: By design, you should calculate the data throughput to ensure that there are no data bubbles in the design. This additional protection is to minimize errors in the system.
tx_ready_err
  • This error is flagged when the transceiver indicates that it is down.
  • The processor needs to probe the transceiver controls.
tx_pcfifo_full_err
  • This error is flagged when at least 1 lane of the transceiver phase compensation FIFO indicates full.
  • The processor needs to probe the correct clocks and data-width settings.
tx_gb_underflow_err
  • This error is flagged when at least 1 instance of the TX gearbox FIFO is having underflow.
  • The processor ensures that the system design provides the correct j204c_txlink_clk frequency of (data rate)/132 to the IP.
tx_gb_overflow_err
  • This error is flagged when at least 1 instance of the TX gearbox FIFO is having overflow.
  • The processor ensures that the system design provides the correct j204c_txlink_clk frequency of (data rate)/132 to the IP.
Table 19.  RX Interrupt Handler Recommendations
Error Type ISR Handler Operation
rx_sysref_lemc_err
  • This error occurs when the SYSREF signal continuously resets the LEMC counter at an unexpected time, which violates the LEMC period.
  • The processor needs to check the setting for all LEMC counters configured on the JESD204C IP converter device and clock chip.
  • By default, the link automatically reinitializes when this signal is asserted.
rx_dll_data_ready_err
  • This error occurs when the Avalon® streaming interface in the JESD204C RX base core does not have backpressure and yet, the upstream device indicates that it is unable to take in data.
  • The processor needs to probe the upstream device to find out why it has stalled and take further action.
Note: By design, you should calculate the data throughput to ensure that there are no data bubbles in the design. This additional protection is to minimize errors in the system.
rx_frame_data_ready_err
  • This error occurs when the Avalon® streaming interface in the RX transport layer does not have backpressure and yet, the upstream device indicates that it is unable to take in data.
  • The processor needs to probe the upstream device to find out why it has stalled and take further action.
Note: By design, you should calculate the data throughput to ensure that there are no data bubbles in the design. This additional protection is to minimize errors in the system.
rx_cmd_ready_err
  • This error occurs when the Avalon® streaming command interface in the RX link layer does not have backpressure and yet, the upstream device indicates that it is unable to take in data.
  • The processor needs to probe the upstream device to find out why it has stalled and take further action.
Note: By design, you should calculate the data throughput to ensure that there are no data bubbles in the design. This additional protection is to minimize errors in the system.
rx_cdr_locked_err
  • This error occurs because of incoming data stream that causes RX PMA to unlock its CDR.
  • The processor may not be able to recover from such error. PMA debug is required.
rx_pcfifo_empty_err
  • This error is flagged when at least 1 lane of the transceiver phase compensation FIFO indicates empty.
  • The processor may not be able to recover from such error. Transceiver debug is required.
rx_pcfifo_full_err
  • This error is flagged when at least 1 lane of the transceiver phase compensation FIFO indicates full.
  • The processor may not be able to recover from such error. Transceiver debug is required.
rx_lane_deskew_err
  • This is a system error.
  • You need to investigate total skew and the E parameter settings.
rx_invalid_sync_header
  • This error occurs when the IP receives “00” or “11” in the expected SH location.
  • Refer to the JESD204C Specifications for action required for hardware.
rx_invalid_eomb
  • This errors occurs when “00001” sequence in the pilot signal is not received at an expected location in the sync word.
  • Refer to the JESD204C Specifications for action required for hardware.
rx_invalid_eoemb
  • This error occurs when the EoEMB identifier in the pilot signal has an unexpected value.
  • Refer to the JESD204C Specifications for action required for hardware.
rx_cmd_par_err
  • The error is flagged when the final parity bit in the command channel data for a given Sync Word does not match the calculated parity for the received command channel bits.
  • Refer to the JESD204C Specifications for action required for hardware.
rx_crc_err
  • This error occurs when the receive CRC generator has calculated a parity which does not match the parity received in the Sync Word.
  • The hardware tries to reinitialize but if the error persists, the processor is required to find out the cause of CRC error.
rx_gb_underflow_err
  • This error is flagged when at least 1 instance of the RX gearbox FIFO is having underflow.
  • This underflow error occurs when the frequency ratio between j204c_rxlink_clk and j204_rxphy_clk is larger than 16:33. In this scenario, the j204c_rxlink_clk clock is unexpectedly faster than the j204c_rxphy_clk clock.
  • When this error occurs, the system needs to reset.
  • To prevent this error from occurring, the frequency ratio of j204c_rxlink_clk and j204_rxphy_clk must be 16:33.
rx_gb_overflow_err
  • This error is flagged when at least 1 instance of the RX gearbox is having overflow.
  • This overflow error occurs when the frequency ratio between j204c_rxlink_clk and j204_rxphy_clk is smaller than 16:33. In this scenario, the j204c_rxlink_clk clock is unexpectedly slower than the j204c_rxphy_clk clock.
  • When this error occurs, the system needs to reset.
  • To prevent this error from occurring, the frequency ratio of j204c_rxlink_clk and j204_rxphy_clk must be 16:33.
rx_sh_unlock_err
  • This error indicates that SH alignment is lost.
  • The hardware always tries to reinitialize for this error.
rx_emb_unlock_err
  • This error indicates that EMB alignment is lost.
  • The hardware always tries to reinitialize for this error.
rx_eb_full_err
  • This error could be caused by the same reason that causes deskew error.
  • You need to investigate total skew and the E parameter settings.
rx_ecc_corrected_err
  • This error keeps track of the EC detected. Intel recommends you to enable this error so that the processor can keep track of the EC detected.
  • The processor can enter error detection and correction routine.
rx_ecc_fatal_err
  • ECC fatal error that indicates bad data has been sent to the upstream device. The severity of this error depends on the system.
  • For example, ultrasound applications may still cope with uncorrectable ECC errors. However, systems where data packets should never be lost, the system may reset the core.