How do I Set up the Tri-Mode Controllers for NVMe*/SAS/SATA Modes?
Content Type: Install & Setup | Article ID: 000029611 | Last Reviewed: 02/18/2025
The Tri-Mode Full featured Intel® RAID Controllers have support for SAS (Serial Attached SCSI)/SATA and NVMe* drives. This support can be set to SAS/SATA only, NVMe only, and SAS/SATA/NVMe. It's possible to change the controller configuration, to optimize its resources according to the mentioned settings. Such configurations are called profiles (also known as operating mode). Each profile has a different support model that affects the maximum number of supported devices.
You can change the profile from the UEFI HII Configuration Utility using the steps below:
Personality | Profile# | Profile Name | Drive Support | Max Physical Drives | Max Virtual Drives |
RAID | 10 | PD64 | SAS/SATA | 64 | 64 |
RAID | 11 | NVMe4 | NVMe | 4 | 64 |
RAID | 12 | PD240 | SAS/SATA | 240 | 240 |
RAID | 13 | PD64_NVMe4 | SAS/SATA/NVMe | 64 | 64 |
JBOD | 20 | PD_240 | SAS/SATA | 240 | 240 |
JBOD | 21 | PD64_NVMe8 | SAS/SATA/NVMe | 64 | 64 |
JBOD | 23 | PD_240 | SAS/SATA | 240 | 240 |
Note | From firmware version 5.080.00-1965 (package 50.8.0-2-66) onwards, only profile options that are compatible with the current personality setting and drive type connected are visible. |