Visible to Intel only — GUID: sam1412835897898
Ixiasoft
1. Agilex™ 7 M-Series General-Purpose I/O Overview
2. Agilex™ 7 M-Series GPIO-B Banks
3. Agilex™ 7 M-Series HPS I/O Banks
4. Agilex™ 7 M-Series SDM I/O Banks
5. Agilex™ 7 M-Series I/O Troubleshooting Guidelines
6. GPIO Intel® FPGA IP
7. Programmable I/O Features Description
8. Documentation Related to the Agilex™ 7 General-Purpose I/O User Guide: M-Series
9. Document Revision History for the Agilex™ 7 General-Purpose I/O User Guide: M-Series
2.5.1. I/O Standard Placement Restrictions for True Differential I/Os
2.5.2. Placement Restrictions for True Differential and Single-Ended I/O Standards in the Same or Adjacent GPIO-B Bank
2.5.3. VREF Sources and Input Standards Grouping
2.5.4. GPIO-B Pin Restrictions for External Memory Interfaces
2.5.5. RZQ Pin Requirement
2.5.6. I/O Standards Implementation Based on VCCIO_PIO Voltages
2.5.7. I/O Standard Selection and I/O Bank Supply Compatibility Check
2.5.8. Simultaneous Switching Noise
2.5.9. HPS Shared I/O Requirements
2.5.10. Clocking Requirements
2.5.11. SDM Shared I/O Requirements
2.5.12. Unused Pins
2.5.13. VCCIO_PIO Supply for Unused GPIO-B Banks
2.5.14. GPIO-B Pins During Power Sequencing
2.5.15. Drive Strength Requirement for GPIO-B Input Pins
2.5.16. Maximum DC Current Restrictions
2.5.17. 1.05 V, 1.1 V, or 1.2 V I/O Interface Voltage Level Compatibility
2.5.18. Connection to True Differential Signaling Input Buffers During Device Reconfiguration
2.5.19. LVSTL700 I/O Standards Differential Pin Pair Requirements
2.5.20. Implementing a Pseudo Open Drain
2.5.21. Allowed Duration for Using RT OCT
2.5.22. Single-Ended Strobe Signal Differential Pin Pair Restriction
6.1. Release Information for GPIO Intel® FPGA IP
6.2. Generating the GPIO Intel® FPGA IP
6.3. GPIO Intel® FPGA IP Parameter Settings
6.4. GPIO Intel® FPGA IP Interface Signals
6.5. GPIO Intel® FPGA IP Architecture
6.6. Verifying Resource Utilization and Design Performance
6.7. GPIO Intel® FPGA IP Timing
6.8. GPIO Intel® FPGA IP Design Examples
Visible to Intel only — GUID: sam1412835897898
Ixiasoft
6.7.3. Timing Analysis
The Quartus® Prime software does not automatically generate the SDC timing constraints for the GPIO IP. You must manually enter the timing constraints.
Follow the timing guidelines and examples to ensure that the Timing Analyzer analyzes the I/O timing correctly.
- To perform proper timing analysis for the I/O interface paths, specify the system level constraints of the data pins against the system clock pin in the .sdc file.
- To perform proper timing analysis for the core interface paths, define these clock settings in the .sdc file:
- Clock to the core registers
- Clock to the I/O registers for the simple register and DDIO modes