5.1.4.6. CRC Checking
FCS(X) = X 32 +X 26 +X 23 +X 22 +X 16 +X 12 +X 11 +X 10 +X 8 +X 7 +X 5 +X 4 +X 2 +X 1 +1
The 32-bit CRC value occupies the FCS field with X31 in the least significant bit of the first byte. The CRC bits are thus received in the following order: X31, X30,..., X1, X0.
If the MAC function detects CRC-32 error, it marks the frame invalid by asserting the following signals:
- rx_err[2] in MAC variations with internal FIFO buffers.
- data_rx_error[1] in MAC variations without internal FIFO buffers.
The MAC function discards frames with CRC-32 error if the RX_ERR_DISC bit in the command_config register is set to 1.
For frames less than the required minimum length, the MAC function forwards the CRC-32 field to the user application if the CRC_FWD and PAD_EN bits in the command_config register are 1 and 0 respectively. Otherwise, the CRC-32 field is removed from the frame.