E-Tile Hard IP Intel Agilex® 7 Design Example User Guide: Ethernet, E-tile CPRI PHY and Dynamic Reconfiguration

ID 683860
Date 8/08/2023
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

2.1.6.3. 100GE PCS Only with Optional (528,514) RS-FEC or (544,514) RS-FEC, and Optional PTP Hardware Design Example

To turn on the System Console and test the hardware design example, follow these steps:

  1. After the hardware design example is configured on the Intel Agilex® 7 device, in the Intel® Quartus® Prime Pro Edition software, on the Tools menu, click System Debugging Tools > System Console.
  2. In the Tcl Console pane, type cd hwtest to change directory to <design_example_dir>/hardware_test_design/hwtest.
  3. Type source main.tcl to open a connection to the JTAG master.
  4. Type pcs_only_traffic_test <number of iteration> to run the specified iteration of PCS only with (528,514) RS-FEC hardware design example test. If no value is specified, the test runs only 1 iteration. Each packet generated for every iterations are in random number of frames, size, and types.
  5. Type pcs_only_traffic_test_pam4 <number of interation> to run the specified iteration of PCS only with (544,514) RS-FEC hardware design example test. If no value is specified, the test runs only 1 iteration. Each packet generated for every iterations are in random number of frames, size, and types.