13.7.2.2.3. Enabling the EMIF Unified Calibration Debug Toolkit in an Existing Design

To enable Unified Toolkit support in an existing design, follow these steps.
  1. Add the following line to the .qsf file: set_global_assignment -name VERILOG_MACRO "ALTERA_EMIF_ENABLE_ISSP=1"
  2. For each EMIF instance in the design, select Add EMIF Debug Interface from the Intel Quartus Prime EMIF Debug Toolkit/On-Chip Debug Port drop-down menu.
  3. Click Generate HDL and compile the design.
Note: If your original EMIF IP version is older than 19.2.1, or if your design was not generated based on the design example, you must regenerate the design beginning with a design example. Follow the instructions in Generating a Design Example with the Debug Toolkit and in Adding Interfaces to an Design Example.