Visible to Intel only — GUID: zpq1558044561543
Ixiasoft
1. Intel® Agilex™ Configuration User Guide
2. Intel® Agilex™ Configuration Details
3. Intel® Agilex™ Configuration Schemes
4. Including the Reset Release Intel® FPGA IP in Your Design
5. Remote System Update (RSU)
6. Intel® Agilex™ Configuration Features
7. Intel® Agilex™ Debugging Guide
8. Intel® Agilex™ Configuration User Guide Archives
9. Document Revision History for the Intel® Agilex™ Configuration User Guide
2.1. Intel® Agilex™ Configuration Timing Diagram
2.2. Configuration Flow Diagram
2.3. Device Response to Configuration and Reset Events
2.4. Additional Clock Requirements for HPS and Transceivers
2.5. Intel® Agilex™ Configuration Pins
2.6. Configuration Clocks
2.7. Intel® Agilex™ Configuration Time Estimation
2.8. Generating Compressed .sof File
3.1.1. Avalon® -ST Configuration Scheme Hardware Components and File Types
3.1.2. Enabling Avalon-ST Device Configuration
3.1.3. The AVST_READY Signal
3.1.4. RBF Configuration File Format
3.1.5. Avalon-ST Single-Device Configuration
3.1.6. Debugging Guidelines for the Avalon® -ST Configuration Scheme
3.1.7. IP for Use with the Avalon® -ST Configuration Scheme: Intel FPGA Parallel Flash Loader II IP Core
3.1.7.4.1. PFL II IP Recommended Design Constraints to FPGA Avalon-ST Pins
3.1.7.4.2. PFL II IP Recommended Design Constraints for Using QSPI Flash
3.1.7.4.3. PFL II IP Recommended Design Constraints for using CFI Flash
3.1.7.4.4. PFL II IP Recommended Constraints for Other Input Pins
3.1.7.4.5. PFL II IP Recommended Constraints for Other Output Pins
3.2.1. AS Configuration Scheme Hardware Components and File Types
3.2.2. AS Single-Device Configuration
3.2.3. AS Using Multiple Serial Flash Devices
3.2.4. AS Configuration Timing Parameters
3.2.5. Maximum Allowable External AS_DATA Pin Skew Delay Guidelines
3.2.6. Programming Serial Flash Devices
3.2.7. Serial Flash Memory Layout
3.2.8. AS_CLK
3.2.9. Active Serial Configuration Software Settings
3.2.10. Intel® Quartus® Prime Programming Steps
3.2.11. Debugging Guidelines for the AS Configuration Scheme
5.1. Remote System Update Functional Description
5.2. Guidelines for Performing Remote System Update Functions for Non-HPS
5.3. Commands and Responses
5.4. Quad SPI Flash Layout
5.5. Generating Remote System Update Image Files Using the Programming File Generator
5.6. Remote System Update from FPGA Core Example
5.6.1. Prerequisites
5.6.2. Creating Initial Flash Image Containing Bitstreams for Factory Image and One Application Image
5.6.3. Programming Flash Memory with the Initial Remote System Update Image
5.6.4. Reconfiguring the Device with an Application or Factory Image
5.6.5. Adding an Application Image
5.6.6. Removing an Application Image
7.1. Configuration Debugging Checklist
7.2. Intel® Agilex™ Configuration Architecture Overview
7.3. Understanding Configuration Status Using quartus_pgm command
7.4. Configuration File Format Differences
7.5. Understanding SEUs
7.6. Reading the Unique 64-Bit CHIP ID
7.7. E-Tile Transceivers May Fail To Configure
7.8. Understanding and Troubleshooting Configuration Pin Behavior
Visible to Intel only — GUID: zpq1558044561543
Ixiasoft
2.5.3.4. SDM I/O Pins for Power Management and SmartVID
SDM pins are also available for the SmartVID power management feature for -V and -E devices.
Intel recommends that you use LTC3888 or LTM4677 to regulate the PMBus. The LTM4677 device is the default setting for the Device > Device and Pin Options > Power Management & VID > Slave device type parameter. Select a regulator you use on your board. If you are using a different PMBus regulator, change the default setting from LTM4677 to Other.
Figure 12. Specifying the Slave Device Type for Power Management and VID
Intel® Quartus® Prime Pro Edition software allows you to control the payload value of the Page command. Some PMBus devices contain more than one page per bank of registers, the Page command allows you to select the target Page per bank registers. The Page payload available range is between 0x00 and 0xFF.
Note: Prior the Intel® Quartus® Prime Pro Edition software release, the Page command selected all banks by default.
Figure 13. Specifying the Page Command Setting
Refer to the Intel® Agilex™ Power Management User Guide for more information about the Power Management and VID implementation guide.
Related Information