Agilex™ 7 Hard Processor System Technical Reference Manual

ID 683567
Date 8/13/2024
Public
Document Table of Contents

19.4.3.2. Transmit Only

When TMOD = 1, any receive data are ignored. The data transfer occurs as normal, according to the selected frame format (serial protocol). Transmit data are popped from the transmit FIFO buffer and sent through the txd line to the target device, which replies with data on the rxd line. At the end of the data frame, the receive shift register does not load its newly received data into the receive FIFO buffer. The data in the receive shift register is overwritten by the next transfer. You should mask interrupts originating from the receive logic when this mode is entered. †