6.1.2.1.2. Master Security

All masters on the system interconnect are expected to drive the Secure bit attribute for every transaction. In addition to Secure bit, each master is assigned a Unique ID that identifies the source of a transaction. Accesses to secure slaves by non-secure masters result in a bus error.

Table 52.  Master Security Bit
Master Secure bit Secure State Non Secure State Source
AXI-AP A*PROT[1] 0 1 Driven by AXI-AP
CCU_IOS A*PROT[1] 0 1 Driven by CCU (transported from MPU and FPGA2HPS)
DMAC A*PROT[1] 0 1 Driven by DMAC
EMACx A*PROT[1] 0 1 Driven by System Manager
EMAC_TBU A*PROT[1] 0 1 Driven by TBU (transported from EMAC or page table attribute)
ETR A*PROT[1] 0 1 Driven by ETR
ETR_TBU A*PROT[1] 0 1 Driven by TBU (transported from ETR or page table attribute)
NAND A*PROT[1] 0 1 Driven by System Manager
SD/MMC HA*USER[1] 0 1 Driven by System Manager
USB HA*USER[1] 0 1 Driven by System Manager
IO_TBU A*PROT[1] 0 1 Driven by TBU (transported from page table attribute)
SDM_TBU A*PROT[1] 0 1

Driven by TBU (transported from page table attribute)