Stratix V Avalon-ST Interface with SR-IOV PCIe Solutions: User Guide

ID 683488
Date 5/02/2016
Public
Document Table of Contents

4.6. Clock Signals

Table 26.  Clock Signals Hard IP Implementation

Signal

Direction

Description

refclk

Input

Reference clock for the Stratix V Hard IP for PCI Express. It must have the frequency specified under the System Settings heading in the parameter editor.

pld_clk

Input

Clocks the Application Layer. You can drive this clock with coreclkout_hip. If you drive pld_clk with another clock source, it must be equal to or faster than coreclkout.

All the interfaces and internal modules of the SR-IOV Bridge use this clock as the reference clock. Its frequency is 125 or 250 MHz.

coreclkout_hip

Output

This is a fixed frequency clock used by the Data Link and Transaction Layers. To meet PCI Express link bandwidth constraints, this clock has minimum frequency requirements as listed in coreclkout_hip Values for All Parameterizations in the Reset and Clocks chapter .

Refer to Stratix V Hard IP for PCI Express Clock Domains in the Reset and Clocks chapter for more information about clocks.