XCVR_C10_RX_ADP_CTLE_EQZ_1S_SEL

A logic option that allows you to control the amount of AC gain on the one-stage equalizer. The amount of AC gain is propotional to the setting where '0' gives the lowest AC gain and '15' gives the largest AC gain. This option is only valid when equalizer operates in manual mode.

Type

Enumeration

Values

  • RADP_CTLE_EQZ_1S_SEL_0
  • RADP_CTLE_EQZ_1S_SEL_1
  • RADP_CTLE_EQZ_1S_SEL_10
  • RADP_CTLE_EQZ_1S_SEL_11
  • RADP_CTLE_EQZ_1S_SEL_12
  • RADP_CTLE_EQZ_1S_SEL_13
  • RADP_CTLE_EQZ_1S_SEL_14
  • RADP_CTLE_EQZ_1S_SEL_15
  • RADP_CTLE_EQZ_1S_SEL_2
  • RADP_CTLE_EQZ_1S_SEL_3
  • RADP_CTLE_EQZ_1S_SEL_4
  • RADP_CTLE_EQZ_1S_SEL_5
  • RADP_CTLE_EQZ_1S_SEL_6
  • RADP_CTLE_EQZ_1S_SEL_7
  • RADP_CTLE_EQZ_1S_SEL_8
  • RADP_CTLE_EQZ_1S_SEL_9

Device Support

  • Intel® Cyclone® 10 GX

Notes

Syntax


set_instance_assignment -name XCVR_C10_RX_ADP_CTLE_EQZ_1S_SEL -to <to> -entity <entity name> <value>