2.3.1. Root Port Legacy Interrupt Status register INTx is stuck HIGH
2.3.2. TLP Bypass Error Status Register may Report Receiver Errors
2.3.3. PCIe CV and PTC Tests in the PCI-SIG Compliance Test Suite may Fail
2.3.4. Returning Incorrect Function Number
2.3.5. Incorrect Return Value for Power Management Register
2.3.6. Register Implementation while using the SR-IOV Feature
2.3.7. Register Implementation while using the Multi-function Feature
2.3.8. Unsuccessful TX Equalization
2.3.9. Link Does Not Degrade With Corrupt Lanes
2.3.10. Warm Reset or PERST Assertion Clears the Sticky Registers
3.1. 843819: Memory Locations May be Accessed Speculatively Due to Instruction Fetches When HCR.VM is Set
3.2. 845719: A Load May Read Incorrect Data
3.3. 855871: ETM Does Not Report IDLE State When Disabled Using OSLOCK
3.4. 855872: A Store-Exclusive Instruction May Pass When it Should Fail
3.5. 711668: Configuration Extension Register Has Wrong Value Status
3.6. 720107: Periodic Synchronization Can Be Delayed and Cause Overflow
3.7. 855873: An Eviction Might Overtake a Cache Clean Operation
3.8. 853172: ETM May Assert AFREADY Before All Data Has Been Output
3.9. 836870: Non-Allocating Reads May Prevent a Store Exclusive From Passing
3.10. 836919: Write of the JMCR in EL0 Does Not Generate an UNDEFINED Exception
3.11. 845819: Instruction Sequences Containing AES Instructions May Produce Incorrect Results
3.12. 851672: ETM May Trace an Incorrect Exception Address
3.13. 851871: ETM May Lose Counter Events While Entering WFx Mode
3.14. 852071: Direct Branch Instructions Executed Before a Trace Flush May be Output in an Atom Packet After Flush Acknowledgment
3.15. 852521: A64 Unconditional Branch May Jump to Incorrect Address
3.16. 855827: PMU Counter Values May Be Inaccurate When Monitoring Certain Events
3.17. 855829: Reads of PMEVCNTR<n> are not Masked by HDCR.HPMN
3.18. 855830: Loads of Mismatched Size May not be Single-Copy Atomic
Visible to Intel only — GUID: kdq1485231366357
Ixiasoft
3. Arm* Cortex*-A53 MPCore* and CoreSight* Errata
This section lists the Arm* Cortex-A53 MPCore* and CoreSight* errata.
Note: This errata only applies if you are using devices which are enabled with the Hard Processor System (HPS).
Each listed erratum has an associated category number which identifies the degree of the behavior.
The categories are as follows:
- Category 1: Behavior has no workaround and severely restricts the use of the product in all, or the majority of applications, rendering the device unusable.
- Category 2: Behavior contravenes the specified behavior and might limit or severely impair the intended use of the specified features, but does not render the product unusable in all or the majority of applications.
- Category 3: Behavior that was not the originally intended behavior but should not cause any problems in applications.
Note: This device only contains category 2 and category 3 errata.
Section Content
843819: Memory Locations May be Accessed Speculatively Due to Instruction Fetches When HCR.VM is Set
845719: A Load May Read Incorrect Data
855871: ETM Does Not Report IDLE State When Disabled Using OSLOCK
855872: A Store-Exclusive Instruction May Pass When it Should Fail
711668: Configuration Extension Register Has Wrong Value Status
720107: Periodic Synchronization Can Be Delayed and Cause Overflow
855873: An Eviction Might Overtake a Cache Clean Operation
853172: ETM May Assert AFREADY Before All Data Has Been Output
836870: Non-Allocating Reads May Prevent a Store Exclusive From Passing
836919: Write of the JMCR in EL0 Does Not Generate an UNDEFINED Exception
845819: Instruction Sequences Containing AES Instructions May Produce Incorrect Results
851672: ETM May Trace an Incorrect Exception Address
851871: ETM May Lose Counter Events While Entering WFx Mode
852071: Direct Branch Instructions Executed Before a Trace Flush May be Output in an Atom Packet After Flush Acknowledgment
852521: A64 Unconditional Branch May Jump to Incorrect Address
855827: PMU Counter Values May Be Inaccurate When Monitoring Certain Events
855829: Reads of PMEVCNTR<n> are not Masked by HDCR.HPMN
855830: Loads of Mismatched Size May not be Single-Copy Atomic