4.2.1.2. TLPBYPASS_ERR_STATUS (Address 0x14190)
When an error is detected, it is recommended that user reads the PF0 AER register inside F-Tile to get detailed information about the error. To clear the previous error status, user needs to clear TLPBYPASS_ERR_STATUS and the corresponding correctable and uncorrectable error status registers in the AER capability structure. After doing that, user can get the new error update from this register.
This register allows user to enable or disable error reporting. When this feature is disabled, the TLPBYPASS_ERR_ STATUS bits associated with an error are not set when the error is detected.
Name | Bits | Reset Value | Access Mode | Description |
---|---|---|---|---|
Reserved | [31:20] | 12’b0 | RO | Reserved |
cfg_uncor_internal_err_sts | [19] | 1'b0 | W1C | Uncorrectable Internal Error |
cfg_corrected_internal_err_sts | [18] | 1'b0 | W1C | Corrected Internal Error |
cfg_rcvr_overflow_err_sts | [17] | 1'b0 | W1C | Receiver Overflow Error |
cfg_fc_protocol_err_sts | [16] | 1'b0 | W1C | Flow Control Protocol Error |
cfg_mlf_tlp_err_sts | [15] | 1'b0 | W1C | Malformed TLP Error |
cfg_surprise_down_err_sts | [14] | 1'b0 | W1C | Surprise Down Error. Available in downstream mode only. |
cfg_dl_protocol_err_sts | [13] | 1'b0 | W1C | Data Link Protocol Error |
cfg_replay_number_rollover_err_sts | [12] | 1'b0 | W1C | REPLAY_NUM Rollover Error |
cfg_replay_timer_timeout_err_sts | [11] | 1'b0 | W1C | Replay Timer Timeout Error |
cfg_bad_dllp_err_sts | [10] | 1'b0 | W1C | Bad DLLP Error |
cfg_bad_tlp_err_sts | [9] | 1'b0 | W1C | Bad TLP Error |
cfg_rcvr_err_sts | [8] | 1'b0 | W1C | Receiver Error |
Reserved | [7:1] | 7'b0 | RO | Reserved |