Visible to Intel only — GUID: nik1410565017323
Ixiasoft
Visible to Intel only — GUID: nik1410565017323
Ixiasoft
6.3.5.11. BFM Log and Message Procedures
These procedures provide support for displaying messages in a common format, suppressing informational messages, and stopping simulation on specific message types.
The following constants define the type of message and their values determine whether a message is displayed or simulation is stopped after a specific message. Each displayed message has a specific prefix, based on the message type in the following table.
You can suppress the display of certain message types. The default values determining whether a message type is displayed are defined in the following table. To change the default message display, modify the display default value with a procedure call to ebfm_log_set_suppressed_msg_mask.
Certain message types also stop simulation after the message is displayed. The following table shows the default value determining whether a message type stops simulation. You can specify whether simulation stops for particular messages with the procedure ebfm_log_set_stop_on_msg_mask.
All of these log message constants are of the type integer.
Constant (Message Type) |
Description |
Mask Bit No |
Display by Default |
Simulation Stops by Default |
Message Prefix |
---|---|---|---|---|---|
EBFM_MSG_DEBUG | Specifies debug messages. |
0 |
No |
No |
DEBUG: |
EBFM_MSG_INFO | Specifies informational messages, such as configuration register values, starting and ending of tests. |
1 |
Yes |
No |
INFO: |
EBFM_MSG_WARNING | Specifies warning messages, such as tests being skipped due to the specific configuration. |
2 |
Yes |
No |
WARNING: |
EBFM_MSG_ERROR_INFO | Specifies additional information for an error. Use this message to display preliminary information before an error message that stops simulation. |
3 |
Yes |
No |
ERROR: |
EBFM_MSG_ERROR_CONTINUE | Specifies a recoverable error that allows simulation to continue. Use this error for data comparison failures. |
4 |
Yes |
No |
ERROR: |
EBFM_MSG_ERROR_FATAL | Specifies an error that stops simulation because the error leaves the testbench in a state where further simulation is not possible. |
N/A |
Yes Cannot suppress |
Yes Cannot suppress |
FATAL: |
EBFM_MSG_ERROR_FATAL_TB_ERR | Used for BFM test driver or Root Port BFM fatal errors. Specifies an error that stops simulation because the error leaves the testbench in a state where further simulation is not possible. Use this error message for errors that occur due to a problem in the BFM test driver module or the Root Port BFM, that are not caused by the Endpoint Application Layer being tested. |
N/A |
Yes Cannot suppress |
Yes Cannot suppress |
FATAL: |