8.6.3. XCVR_C10_TX_SLEW_RATE_CTRL

Pin planner or Assignment Editor Name

Transmitter Slew Rate Control

Description

Specifies the slew rate of the output signal. The valid values span from the slowest rate to the fastest rate.

Note: Slew_R6 and Slew_R7 are not used.
Table 238.  Available Options

Value

Description

SLEW_R0 to SLEW_R5

R0 is the slowest rate. R5 is the fastest rate.

If QSF is not specified, the following table lists the default values.

Table 239.  Default Values

PCIe

Value

Default Slew Rate

PCIe Gen1

SLEW_R4

PCIe Gen2

SLEW_R5

Non-PCIe

Value

(VCCT/VCCR)

Default Slew Rate

Data rate < 1G Data rate ≥ 1G to < 3G Data rate ≥ 3G to < 6G Data rate ≥ 6G

0.95 V

SLEW_R0

SLEW_R2 SLEW_R3 SLEW_R5

Assign To

TX serial data pin.

Syntax

set_instance_assignment -name XCVR_C10_TX_SLEW_RATE_CTRL <value> -to <tx_serial_data pin name>