2.6.1.4. Rate Match FIFO for GbE
The GbE protocol requires the transmitter to send idle ordered sets /I1/ (/K28.5/D5.6/) and /I2/ (/K28.5/D16.2/) during inter-packet gaps (IPG) adhering to the rules listed in the IEEE 802.3-2008 specification.
The rate match operation begins after the synchronization state machine in the word aligner indicates synchronization is acquired by driving the rx_syncstatus signal high. The rate matcher deletes or inserts both symbols /K28.5/ and /D16.2/ of the /I2/ ordered sets as a pair in the operation to prevent the rate match FIFO from overflowing or underflowing. The rate match operation can insert or delete as many /I2/ ordered sets as necessary.
The following figure shows a rate match deletion operation example where three symbols must be deleted. Because the rate match FIFO can only delete /I2/ ordered sets, it deletes two /I2/ ordered sets (four symbols deleted).
The following figure shows an example of rate match FIFO insertion in the case where one symbol must be inserted. Because the rate match FIFO can only insert /I2/ ordered sets, it inserts one /I2/ ordered set (two symbols inserted).
rx_std_rmfifo_full and rx_std_rmfifo_empty are forwarded to the FPGA fabric to indicate rate match FIFO full and empty conditions.
The rate match FIFO does not delete code groups to overcome a FIFO full condition. It asserts the rx_std_rmfifo_full flag for at least two recovered clock cycles to indicate rate match FIFO full. The following figure shows the rate match FIFO full condition when the write pointer is faster than the read pointer.
The rate match FIFO does not insert code groups to overcome the FIFO empty condition. It asserts the rx_std_rmfifo_empty flag for at least two recovered clock cycles to indicate that the rate match FIFO is empty. The following figure shows the rate match FIFO empty condition when the read pointer is faster than the write pointer.
In the case of rate match FIFO full and empty conditions, you must assert the rx_digitalreset signal to reset the receiver PCS blocks.