Article ID: 000095874 Content Type: Product Information & Documentation Last Reviewed: 06/05/2024

Why is the F-tile unresponsive for the Agilex™ 7 FPGA device with Density Code 008 or 006 and Package Code R16A or R24C? 

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    Due to a problem in the Quartus® Prime Pro Edition Software version 23.2 and earlier, one of the F-Tiles (IO Bank 13A) is not correctly configured for the following devices:

    • AGF 006 R16A
    • AGF 006 R24C
    • AGF 008 R16A
    • AGF 008 R24C
    Resolution

    A patch is available to fix this problem for the Quartus® Prime Pro Edition Software version 23.1 and version 23.2. 

    Download and install patch 0.28fw for the Quartus® Prime Pro Edition Software version 23.1 from the appropriate link below, then re-generate your programming file.

     

    Download and install patch 0.05fw for the Quartus® Prime Pro Edition Software version 23.2 from the appropriate link below, then re-generate your programming file.

    This problem is scheduled to be fixed in a future release of the Intel® Quartus® Prime Pro Edition Software.

     

     

    Related Products

    This article applies to 1 products

    Intel Agilex® 7 FPGAs and SoC FPGAs