Critical Issue
The latest device firmware for the Quartus® Prime Pro Edition Software version 23.2 can be downloaded from the following links.
Fixes for the following problems are included in the latest release (The newest release contains all prior fixes and supersedes earlier device firmware releases).
Change Log
Firmware version 0.27fw:
1. Firmware fix to address issues where some Agilex™ devices are not able to configure F-Tile correctly.
Devices affected:
- AGF 006 R16A
- AGF 008 R16A
- AGF 006 R24C
- AGF 008 R24C
2. The patch fixes an issue encountered when using the Post-fit Signaltap feature with preserved partitions.
3. Fix Intermittent failure observed only on error recovery/corruption flows where corruption happens prior to SDM loading the NOCSSM firmware.
4. Fix write data inversion (crosstalk) between adjacent channels that caused some M20K channels to fail.
5. Resolve issue: Quartus® Programmer status feature is broken.
Firmware version 0.30fw:
Firmware fix to resolve an issue where occasionally, in HPS-first mode, the GPIO output was not seen in bank 2D after upgrading to firmware version 23.2.
Please also see the following links:
- Updating the SDM Firmware in the Agilex™ FPGA Configuration User Guide
- Updating the SDM Firmware in the Stratix® 10 FPGA Configuration User Guide
Download the latest Device Firmware from the following links.
- Patch 0.30FW for the Quartus® Prime Pro Edition Software for Windows (.exe)
- Patch 0.30FW for the Quartus® Prime Pro Edition Software for Linux (.run)
- Readme for Patch 0.30FW for the Quartus® Prime Pro Edition Software for Windows (.txt)
Note:
- Patches must be applied to the Quartus® Prime Pro Edition Software and the Quartus® Prime Pro Edition Software Programmer and Tools.
- Recompilation is not required.
- All programming files should be recreated.
- Re-run programming file generation or conversion using the Quartus® Prime Software programming file generator.