Article ID: 000094631 Content Type: Product Information & Documentation Last Reviewed: 06/15/2023

Intel Agilex® Configuration User Guide - Remote System Update (RSU) - Figure 85. Remove Application Image is incorrect

Environment

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Description

Figure 85. Remove Application Image, in section 5.6.6 Removing an Application Image, in the Intel Agilex® 7 FPGA Configuration User Guide is incorrect:

UG-20205

ID: 683673

Version 2022.12.05

5.6.6. Removing an Application Image

Resolution

Incorrect information in Figure 85: % qspi_write_one_word 0x002ec028 0x004A8028.

Correct information is: %qspi_write_one_word 0x004A8028 0x00000000.

The correct figure should look like the image shown below:

% qspi_write_one_word 0x004A0028 0x00000000
% qspi_write_one_word 0x004A8028 0x00000000

This updated information has been added in the Intel Agilex® 7 FPGA Configuration User Guide version 2023.04.28.

Related Products

This article applies to 1 products

Intel Agilex® 7 FPGAs and SoC FPGAs