Article ID: 000094428 Content Type: Error Messages Last Reviewed: 11/23/2024

Error(19192): File <filename>.sof is incomplete - Power management settings are not set up appropriately on VID part

Environment

  • Intel® Quartus® Prime Pro Edition
  • 25G Ethernet Intel® FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    This error might be seen in the Quartus® Prime Pro Edition Software when programming the .sof file to Stratix® 10 FPGA - Transceiver TX SI Development Kit - DK-SI-1STX-E-A.

     

     

    Resolution

    To work around this error, you need to put the following complete SmartVID settings  into the Quartus® Prime Software project QSF file:

    set_global_assignment -name VID_OPERATION_MODE "PMBUS MASTER"

    set_global_assignment -name PWRMGT_BUS_SPEED_MODE "100 KHZ"

    set_global_assignment -name PWRMGT_SLAVE_DEVICE_TYPE LTM4677

    set_global_assignment -name PWRMGT_SLAVE_DEVICE0_ADDRESS 47

    set_global_assignment -name PWRMGT_SLAVE_DEVICE1_ADDRESS 48

    set_global_assignment -name PWRMGT_SLAVE_DEVICE2_ADDRESS 00

    set_global_assignment -name PWRMGT_SLAVE_DEVICE3_ADDRESS 00

    set_global_assignment -name PWRMGT_SLAVE_DEVICE4_ADDRESS 00

    set_global_assignment -name PWRMGT_SLAVE_DEVICE5_ADDRESS 00

    set_global_assignment -name PWRMGT_SLAVE_DEVICE6_ADDRESS 00

    set_global_assignment -name PWRMGT_SLAVE_DEVICE7_ADDRESS 00

    set_global_assignment -name PWRMGT_TRANSLATED_VOLTAGE_VALUE_UNIT VOLTS

    set_global_assignment -name PWRMGT_PAGE_COMMAND_ENABLE ON

    set_global_assignment -name USE_PWRMGT_SCL SDM_IO14

    set_global_assignment -name USE_PWRMGT_SDA SDM_IO11

    set_global_assignment -name USE_CONF_DONE SDM_IO16

    set_global_assignment -name USE_INIT_DONE SDM_IO0

    set_global_assignment -name USE_SEU_ERROR SDM_IO13

    Related Products

    This article applies to 2 products

    Intel® Stratix® 10 TX FPGA
    Intel® Stratix® 10 TX Signal Integrity Development Kit