Article ID: 000094125 Content Type: Troubleshooting Last Reviewed: 03/19/2023

What is the latest device firmware available for the Intel® Quartus® Prime Pro Edition Software version 22.4?

Environment

  • Intel® Quartus® Prime Pro Edition
  • Intel® Quartus® Prime Pro Edition Programmer and Tools
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT

    Critical Issue

    Description

    The latest device firmware for the Intel® Quartus® Prime Pro Edition Software version 22.4 can be downloaded from the following links.

    Fixes for the following problems are included in the latest release (The newest release contains all prior fixes and supersedes earlier device firmware releases).

    Change Log

    Firmware version 0.03fw:

    • Fix NW formatter tool to cover the override scenario where memories located in last bRAM column in the array are overwritten. The propagation configuration time was increased.
    • Firmware update to fix the issue where odd number of headers are not paged correctly when copied from via ROM into local buffer. Add dedicated case for odd number of headers.

    Firmware version 0.06fw:

    • Intel® Stratix® 10 Remote System Update for SoC: Factory Update Images may fail with errors resulting in corrupt RSU CPB tables if the last slot of the CPB table is in use (unavailable) or if the Factory Update Image uses the top (last slot) of the CPB table.
    • Intel Agilex® FPGA: Intermittent failures may be seen when the HPS Cold Reset Pin is used in FPGA First boot mode in ASx4 configuration mode.
    • Intel Agilex® FPGA: Remote System Update may fail to recover after using an incorrect device application image.

    Firmware version 0.21fw:

    • Fixes a bug in the Programming File Generator GUI - When the address for partition P1 was entered manually with the same value that the .map file for the automatically-generated file indicated, the .rpd files did not match.

     

    Please also see the following:

     - Updating the SDM Firmware in the Intel Agilex® FPGA Configuration User Guide

     - Updating the SDM Firmware in the Intel® Stratix® 10 FPGA Configuration User Guide

    Resolution

    Download the latest Device Firmware from the following links.

    Note:  

    • Patches must be applied to the Intel® Quartus® Prime Pro Edition Software and the Intel® Quartus® Prime Pro Edition Software Programmer and Tools.

    • Re-compilation is not required.

    • All Programming files should be re-created.

      •   Re-run programming file generation or conversion using the Intel® Quartus® Programming File Generator.  

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 FPGAs and SoC FPGAs