Due to a problem in the Quartus® Prime Pro Edition Software version 22.4 and 23.1, the F-Tile Ethernet Hard IP and F-tile Auto-Negotiation and Link Training for Ethernet IP will fail to simulate when the client interface is set as MII PCS only, PCS66 OTN and PCS66 FlexE when using on Agilex™ 7 devices with the following OPNs:
- AGMA032R31Bxxxx
- AGMA039R31Bxxxx
- AGMB032R31Bxxxx
- AGMB039R31Bxxxx
- AGME032R47Axxxx
- AGME039R47Axxxx
- AGMF032R47Axxxx
- AGMF039R47Axxxx
- AGMG032R47Axxxx
- AGMG039R47Axxxx
- AGMH032R47Axxxx
- AGMH039R47Axxxx
To avoid this simulation failure, you can adopt the following two workarounds:
- Change the device OPN. The simulation will pass if the OPN is not in the above description list.
- Change the client interface. The simulation will pass if the client interface is set as MAC segmented or MAC Avalon ST.
This problem will be fixed in a future release of the Quartus® Prime Pro Edition Software.