Article ID: 000093349 Content Type: Troubleshooting Last Reviewed: 10/31/2023

Why does compilation fail for the F-Tile Ethernet Intel® FPGA Hard IP designs with Advanced Mode enabled?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 22.4, when Advanced mode is selected from the F-Tile Ethernet Intel® FPGA Hard IP GUI options, you might observe compilation failure.

    This is because the Advanced mode is only supported for the following Intel Agilex® F-tile device OPNs:

    • AGIx040R39AxxxR0
    • AGIx022R31BxxxAA
    • AGIx027R31BxxxAA
    • AGIx027R29AxxxR3
    • AGIx023R18AxxxR0
    • AGFx022R31CxxxAA
    • AGFx027R31CxxxAA
    • AGFx027R24CxxxR2
    • AGFx012R24CxxxAA
    • AGFx014R24CxxxAA

     

    Resolution

    There is no workaround available.

    For any other Intel Agilex® F-tile device OPNs, you must disable the Advanced mode to pass the compilation.

    Related Products

    This article applies to 1 products

    Intel Agilex® 7 FPGAs and SoC FPGAs