Article ID: 000089646 Content Type: Error Messages Last Reviewed: 01/09/2023

Critical Warning(12677): No exact pin location assignment(s)

Environment

  • Intel® Quartus® Prime Pro Edition
  • High Bandwidth Memory (HBM2) Interface Intel® FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    You may see this Critical Warning message in Intel® Quartus® Prime Pro Edition Software version 22.1 and earlier when compiling an Intel® Stratix® 10 design containing the High Bandwidth Memory (HBM2) Interface Intel® FPGA IP.
    The warning will be associated with missing location assignments for m2u_bridge conduit signals.

     

     

    Resolution

    This message can be safely ignored for the m2u_bridge conduit signals since they are not connected to physical pins.

    This message will be automatically suppressed starting from Intel Quartus Prime Pro Edition Software version 22.2.

    Related Products

    This article applies to 2 products

    Intel® Stratix® 10 DX FPGA
    Intel® Stratix® 10 MX FPGA